High performance- Maintains precise control of temperature, humidity, and CO2.
Easy installation and handling- start an experiment easily and setup can be done within 15 mins.
Set model- All necessary parts comes with one part number.
Uniform temperature
On the top lid (TOP heater), heated glass warms the entire chamber effectively by radiant heat. Uniform temperature distribution can be achieved with all vessels.
Accurate temperature control
The sensor monitors the sample (media) temperature and feedbacks to the controller. The TOP heater will be automatically regulated and maintain the sample (media) temperature at the setting value.
High Humidity
Applied internal humidifier which is the same method as conventional CO2 incubator. BATH heater is railed under the water reservoir and heats the distilled water effectively for high humidity. Possible to add the water from the tube by using syringe.
Stable CO2 regulation
Stable concentration of CO2 gas will gently blow inside the chamber constantly throughout the experiment.
①STXG: For 100% CO2 gas cylinder
CO2 concentration: 5.0% -20.0%
②STXF: For premixed gas cylinder
5.0% CO2 +95% Air
Usability
Connect ①②③ & ⑧Power plug to start an experiment.
① Chamber
② GAS OUT
③ CO2 IN
④ PC link cable connection
⑤ Sub heater port (for optional items)
⑥ External sample temperature sensor
⑦ Warming Box, Gas Mixer link (for optional items)
⑧ Power plug
For short WD and high NA objective lens use
Possible to focus on the sample and move your objective lens X-Y axis freely with short WD and high NA objective lens.
Smart objective lens heater
Universal design objective lens heater which is compatible with up to φ 40mm diameter objective lens. The connection part of the cable is magnetically detachable to prevent the entanglement of the cable and revolver from damaging. The connector part can also be locked.
Set model
SET package ncludes everything you need to start your live cell-imaging.
Option
GM-8000- Hypoxia gas mixer
It can be used with either STXG or STXF controller for various chambers.
O2 range: 0.1 - 18.0%(0.1% accuracy)
CO2 range: 5.0 - 20.0% (0.1% accuracy)
Flowrate: 150 - 200ml/min
PMD-D35- Programmable fluidic control system
Continuous Perfusion: 40μL/min - 100μL/min
Media Exchange Number: Maximum 10times
Drug Delivery: 20μL –
Mixing Number: Maximum 10 times
TTL signal IN/OUT
KSX-TYPE1- Simple media exchange & perfusion system
Pump flow rate: 0 - 2.86ml/min (By using the attached tube)
KSX-TYPE2- Drug delivery system
Dosage: 20μℓ - 100μℓ
HUMID2ST External humidifier
Temp. setting range: Ambient+5℃ - 60.0℃
Bottle capacity: 200ml
Advantages
No need to refill internal water for 3-4days
Achieves stable humidity.